SMS commands

اكواد تفعيل SMS Commands GT06N جهاز تتبع المركبات

اكواد تفعيل SMS Commands GT06N جهاز تتبع المركبات

mbfallata
لتفعيل وبرمجة مختلف الأجهزة والحصول على برنامج التتبع تواصل معنا واتساب: +966570960313   اوامر واكواد الفحص والاستعلام GT06N Query SMS Commands No. الوظيفة الأمر/الكود الرد الشرح 1 Check GT06N firmware version VERSION# e.g.[VERSION]GT06B_10_8MM_B25_V11_LA [BUILD]2013/01/04 17:45   2 Check GT06N parameters PARAM# e.g.GPS report on time interval:IMEI:868120103643505;TIMER:20,20; SENDS:5; SOS:13730454825,,;Center Number:;Sensorset:10,1,5,1; Defense time:10;TimeZone:E,8,0; GPS report on distance interval:IMEI:868120103643505;Distance:200; SENDS:5; SOS:13730454825,,;Center Number:;Sensorset:10,1,5,1; Defense time:10;TimeZone:E,8,0;   3 Query GT06N network setting GPRSSET# e.g.GPRS:ON; APN:CMNET,,;Server:1,hgt06.szdatasource.com,8841,0;URL:https://maps.google.com/maps?q=;   4 Check GT06N status STATUS# e.g.Battery:3.41V,Battery too low! Warning; GPRS:Link Up; GSM SignalLevel:Strong; GPS:Successful positioning, SVS Used in fix:10(11),GPS Signal Level:32,31,32,31,28,29,29,36,32,33; ACC:OFF;Defense:OFF   5 Check position status WHERE# e.g.Current position!Lat:N22.577156,Lon:E113.916748,Course:0.00,Speed:0.00Km/h,DateTime:2013-01-08 17:35:32   6 Check URL URL# e.g.<01-0817:36>https://maps.google.com/maps?q=N22.577156,E113.916748   7 Check position POSITION#OR123 e.g.GPS located: <01-0817:36>https://maps.google.com/maps?q=N22.577156,E113.916748GPS not located: GPS not fixed, please wait for a while, and then try again.   8 Check geo fence status FENCE# e.g.FenceType:Circle, ON, Latitude:N22.577091,Longitude:E113.916748, radius:600m, in out:IN or OUT, alarm type:1FenceType:Circle, OFF, Latitude:0.000000, Longitude:0.000000,radius:0m, in out:IN or OUT, alarm type:1   9 Check moving status MOVING# e.g.Moving Switch:OFF; Radius:300m; Alarm type:1Moving Switch:ON; Lat:N22.577080; Lon:E113.916794; Radius:300m;Alarm type:1   GT06N Query SMS Commands روابط ذات صلة: اوامر واكواد الاعدادات GT06N Settings SMS Commands No. الوظيفة الأمر/الكود الرد الشرح   GT06N SETTING CLASS       1 Set APN APN, [apnname]#ORAPN, [apnname],[user],[pwd]#   Close automatic APN and set by yourself. APN#   Check the current APN parameters. 2 Set automatic APN ASETAPN, [X]#   X=ON/OFF;ON: open automatic APN;OFF: close automatic APN. ASETAPN#   Check automatic APN status 3 Set server parameters SERVER,mode,domainName/IP,port,protocol#   eg: SERVER,1,www.ydpat.com,8011,0#SERVER,0,211.154.135.113,8011,0#mode = 1 means set with domain namemode = 0 means set with ip address protocol = 0 means connect server with TCP protocolprotocol = 1 means connect server with UDP protocol SERVER#   Check the current sever parameters 4 Set GMT parameter For GT06N GMT,[A],[b],[C]#   A:E or W;”E” means eastern time zone, “W” means western time zone;default:EB:0~12;time zone default:8C:0/15/30/45;half time zone;default:0 GMT#   Check the current time zone parameters 5 Restore GT06N to factory FACTORY#   Restore to factory setting 6 Edit URL EURL,network links#   set the network links for latitude and longitude, default: https://maps.google.com/maps?q= EURL#   Check the current URL 7 GPRS switch GPRSON,X#   X=0 or 1;”1″ means GPRS ON, “0” means GPRS OFF, default:1 GPRSON#   Check the current GPRS status 8 Reboot GT06N RESET#   The device would reboot in 20S after receiving the command. 9 GPRS blocking alarm GPRSALM,X#   X=ON/OFF, default: OFF GPRSALM#   Check the GPRS alarm status 10 SOS setting SOS,A,[phone number 1][,phone number 2][,phone number 3]#   Add SOS phone number. SOS,D,[sequence number 1][, sequence number 2][,sequence number 3]#   Delete the phone number according to the sequence number. SOS,[D],[phone number]#   Delete the matching SOS phone number. SOS#   Check the SOS phone number. 11 Center phone number setting CENTER, A,[phone number]#   Add center phone number. CENTER, D#   Delete center phone number. CENTER#   Check the center phone number. 12 Heartbeat interval setting HBT,[T1],[T2]#   T1 ranges 1~19(minutes), heartbeat package upload interval when ACC ON; default is 3;T2 ranges 1~19 (minutes), heartbeat package upload interval when ACC OFF; default is 5; HBT#   Check the current parameters of T1 and T2. 13 Set GPS data sending interval TIMER,[T1],[T2]#   T1 ranges 5~18000 or 0(seconds), upload interval when ACC ON, 0 means no upload, default is 10;T2 ranges 5~18000 (seconds), upload interval when ACC OFF, default is 10; TIMER#   Check the current parameters of T1 and T2. 14 Set distance interval of GPS data sending DISTANCE,[D]#   D ranges 50~10000 or 0(meters), distance interval, default is 300; DISTANCE#   Check the current distance interval. 15 Set the angle upload ANGLEREP,[X][,A][,B]#   X=ON/OFF, default:ONA=5~180 degrees, diversion angle degree, default:30 degrees;B=2~5 seconds, detecting time, default:3 seconds, ANGLEREP,OFF#   Close the angle upload. ANGLEREP#   Check the angle upload status and its parameters. 16 Set the upload for ACC status change ACCREP,[A]#   A=ON/OFF, upload for ACC status change, default: ON ACCREP#   Check the upload for ACC status change. 17 Set the GPS data sending batch BATCH,[A][,N]#   A= A=ON/OFF, data sending batch function on or off, default:OFFN=1~50, N means the number of messages in the batch, default:10; BATCH#   Check the number of messages in a batch. 18 Set the delay of the defense DEFENSE,[A]#   A= 1~60 (minute), delay of the defense, default:10 (minutes). DEFENSE#   Check the parameters of the defense. 19 Set vibration sensor detecting time SENSOR,<A>,[,B][,C]#   A=10-300 seconds,detecting time. Default: 10 secondsB-10-300 seconds, alert delay. Deault:180 seconds C=1-3000 minutes, vibration alert interval. Default: 30 minutesSENSOR# Check the parameter of the status 20 Set the GPS controlled time by sensor SENDS,[A]#   A=0-300(minute), time duration for GPS to work once vibration detected, 0 means GPS always on work, default: 5(minute) SENDS#   Check the parameters of the time. 21 Disarm DSRESET#   DSRESET# Cancel the current Arm status 22 Clear the backup data CLEAR#     23 Set the static data filtering SF,[A][,B]#   A=ON/OFF;static drift filtering switch;default: ONB=10-1000(m);maximal filtering distance;default: 100(m); SF#   Check the parameters. 24 Set the petrol/electricity control RELAY,[A]#   A=0/1;0 means connection, 1 means cut off;default: 0. RELAY#   Check the status of the control. 25 Set delay time of voice monitor DELAY,<A>#   A=0、5-18 seconds; Default: 10 seconds (Enter Listen-In after 10 senconds calling) 26 Set the fence alarm FENCE,[B],0,[D],[E],[F],[X],[M]#   circle area;B=ON/OFF, open or close fence alarm, default:close;D=the latitude of the circle center;E=the longitude of the circle center;F=1~9999, the fence radius, unit:100 meters; X=IN/OUT;IN: alarming when get in the fence, OUT: alarming when get out the fence, blank means both alarming when get in or get out the fence, default: blank.M=0/1;way of alarming, 0:GPRS only, 1:SMS+GPRS, default:1 FENCE,[B],1,[D],[E],[F],[G][,X][,M]#   rectangle areaB=ON/OFF, open or close fence alarm, default:close;D=the latitude of the position 1;range:-90 ~90(degree);E=the longitude of the position 1;range:-180 ~180(degree);F=the latitude of the position 2;range:-90 ~90(degree);G=the longitude of the position 2;range:-180 ~180(degree);the latitude supports “N/S” or “+/- ” coming before it’s value;the longitude supports “E/W” or “+/- ” coming before it’s value;; FENCE#   Check the parameters of
الأوامر النصية لجهاز FMB120 SMS Commands

الأوامر النصية لجهاز FMB120 SMS Commands

mbfallata
لتفعيل وبرمجة مختلف الأجهزة والحصول على برنامج التتبع تواصل معنا واتساب: +966570960313 ٍSystem Parameters/FMB120 SMS Commands Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 138 Uint8 0 0 8 1 – Ignition Movement source 2 – Accelerometer 4 – GNSS 8 – CAN Speed 133 Uint8 0 0 1 0 – GNSS Speed Source 1 – OBD / CAN 106 Uint8 1 0 1 0 – Disable Static navigation 1 – Enable 112 Uint8 1 0 3 1 – Movement Static navigation source 2 – Ignition 3 – Movement and Ignition 107 Uint8 2 0 2 0 – After Position Fix Send/Save records without TS 1 – Always 2 – After Time Sync 108 Uint8 1 0 1 0 – Disable LED Indication 1 – Enable 109 Uint8 10 1 15 0 – Undefined GNSS source 1 – Beidou only 2 – Glonass only 3 – Glonass and Beidou not allowed 4 – Galileo only 5 – Galileo and Beidou 6 – Galileo and Glonass 7 – Galileo, Glonass and Beidou not allowed 8 – Gps only 9 – Gps and Beidou 10 – Gps and Glonass 11 – Gps, Glonass and Beidou not allowed 12 – Gps and Galileo 13 – Gps, Galileo and Beidou 14 – Gps, Galileo and Glonass 15 – Gps, Galileo, Glonass and Beidou and not allowed 110 Uint8 0 0 1 0 – On need Battery charge mode 1 – After ignition on 113 Uint8 0 0 1 0 – Codec 8 Data Protocol 1 – Codec 8 Extended 135 Uint8 0 0 1 0 – DIN2/AIN1 Input mode 1 – Ground Sense Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 102 Uint8 2 0 4 0 – Disable Sleep settings 1 – GPS sleep 2 – Deep sleep 3 – Online Deep sleep 4 – Ultra Deep sleep 6 – Power Off sleep (only for FMB965) 103 Uint16 1 1 3000 Minutes Timeout                             Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 101 Uint8 4 1 14 1 – DIN 1 Ignition settings 2 – Accelerometer 3 – Digital Input or Accelerometer 4 – Power Voltage 5 – Digital Input or Power Voltage 6 – Accelerometer or Power Voltage 7 – Digital Input, Accelerometer, or Power Voltage 8 – Engine RPM 9 – Digital Input or Engine RPM 10 – Accelerometer or Engine RPM 11 – Digital Input, Accelerometer or Engine RPM 12 – Power Voltage or Engine RPM 13 – Digital Input, Power Voltage or Engine RPM 14 – Accelerometer, Power Voltage or Engine RPM 104 Uint16 30000 0 30000 mV High voltage 105 Uint16 13200 0 29999 mV Low voltage Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 19001 Uint16 5 1 60 Seconds Movement Start Delay 19002 Uint16 60 5 300 Seconds Movement Stop Delay Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 900 Uint8 1 0 3 0 – Gps only Synchronization settings 1 – NITZ and NTP 2 – NTP 3 – NITZ 901 Uint8 0 0 24 Hours NTP Resync 902 Char “avl1.teltonika.lt” 0 55 String NTP server 1 903 Char “pool.ntp.org” 0 55 String NTP server 2 Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 169 Uint8 2 0 2 0 – Disabled Accelerometer Auto Calibration 1 – Once 2 – Continuous 170 Uint8 1 0 1 0 Disabled Gravity Filter 1 Enabled FMB120 System Sarameters SMS Commands ٍGPRS Parameter/FMB120 SMS Commands Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 1000 Uint32 300 30 259200 Seconds Open link timeout 1001 Uint16 30 5 300 Seconds Response timeout 1002 Uint8 0 0 1 0 – Newest Sort by 1 – Oldest 1003 Uint16 0 0 300 Seconds Network ping timeout Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 2000 Uint8 1 0 1 0 – Disable GPRS context 1 – Enable 2001 Char “” 0 32 String APN 2002 Char “” 0 32 String APN username 2003 Char “” 0 32 String APN password Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 2004 Char “” 0 55 String Domain 2005 Uint16 0 0 65535 Number Port 2006 Uint8 1 0 1 0 – TCP Protocol 1 – UDP Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 2010 Uint8 0 0 3 0 – Disable Backup Server Mode 1 – Backup 2 – Duplicate 3 – EGTS 2007 Char “” 0 55 String Backup Server Domain 2008 Uint16 0 0 65535 Number Backup Server Port 2009 Uint8 0 0 1 0 – TCP Backup Server Protocol 1 – UDP Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 13003 Uint8 1 0 1 0 – Disable FOTA WEB Status 1 – Enable 13000 Char fm.teltonika.lt 0 55 String FOTA WEB Domain 13001 Uint16 5000 0 65535 Number FOTA WEB Port 13002 Uint16 720 30 65535 Number FOTA WEB Period GPSR Parameters/FMB120 SMS Commands SMS-Call Settings/FMB120 SMS Commands Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 3000 Uint8 0 0 1 0 – Disable Allow SMS data sending 1 – Enable 3001 Char “” 0 16 String Data Send Number Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 3003 Char “” 0 5 String Login 3004 Char “” 0 5 String Password 3006 Uint16 UTC+00:00 UTC-12:00 UTC+13:00 Time zone SMS event Time Zone Parameter ID Parameter Type Default value Value range Value Parameter name Min Max 3005 Uint8 0 0 4 0 – Do nothing Incoming call action 1 – Hangup 2 – Report position 3 – Spy call 4 – Auto answer Parameter ID Parameter Type Default value Value range
تراكيفاي © 2024 . جميع الحقوق محفوظة